How often do you actually consider your hot water, which automatically appears from your shower and faucet each day? Chances are that you do not, except for those annoying occasions when it does not appear at all.
This problem is easily solved, however, with the installation of a hot water recirculation pump. A device that rapidly draws hot water from your boiler and sends it quickly throughout the piping system to your awaiting needs. But not all recirculation pumps are created equal. Most pumps are designed to run continuously, wasting vast amounts of energy, raising excessive utility expenses, and increasing unnecessary pressure on pipes, leading to premature deterioration.
That is where we come in. Enovative Kontrol Systems’ patented D’MAND CIRC® uses smart technology flow and temperature sensors to turn the pump off when it does not need to run. In many large apartment buildings this may only be an hour per day or less, compared with 24/7 cycle of conventional pumps. This represents the most effective and efficient method of operating a hot water recirculation pump that is available to building owners.
Demand Pump Systems
| Part No. | Name | Description |
|---|---|---|
| 25C99-11 | D’MAND CIRC | 99-Series Pump and Controls/ 2.5″ Copper T Fitting |
| 125C99-11 | D’MAND CIRC | 99-Series Pump and Controls/ 1.25″ Copper T fitting |
| 15C99-11 | D’MAND CIRC | 99-Series Pump and Controls/ 1.5″ Copper T fitting |
| 2C99-11 | D’MAND CIRC | 99-Series Pump and Controls/ 2″ Copper T fitting |
| 99-11 | D’MAND CIRC | 99-Series Pump and Controls/ No T fitting |
| 125CTA | Custom Tee (Flow Switch Housing) | 1.25″ Custom Copper T Flow Switch Housing |
| 15CTA | Custom Tee (Flow Switch Housing) | 1.5″ Custom Copper T Flow Switch Housing |
| 2CTA | Custom Tee (Flow Switch Housing) | 2″ Custom Copper T Flow Switch Housing |
| 25CTA | Custom Tee (Flow Switch Housing) | 2.5″ Custom Copper T Flow Switch Housing |
Guide Spec: SECTION 22 1123 DOMESTIC WATER RECIRCULATION PUMPSPART 1 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. On-demand domestic hot water recirculating system with pumps, control boxes, water demand sensors, temperature sensors, an…
Installation Instruction VideoThis is a 5 minute installation video. This will give you an idea of what a typical installation looks like. (Note: This is not meant for training purposes) For contractors, please…
Product ManualThe product manual for the D ’MAND CIRC….
SpecificationsSpecifications for the D ’MAND CIRC….
WHITE PAPER: D’MAND CIRC®White Paper: D’MAND CIRC Guide to the D’mand Circ Text: Reducing High Energy Bills Related To Central Water Heating Systems – A Guide to D’MAND CIRC® Application…
ICC-ES PMG 1112 Final ReportEnovative demand pumps such as the D’MAND CIRC are certified and evaluated by ICC & IAPMO to conform to building codes and standards. It is certified for ICC’s Inte…
WarrantyProduct warranty for the D’MAND CIRC…
Pepperdine Case StudyCase study on a Pepperdine University Dorm. Demand Pump Case Study Text: Pepperdine University is widely known for its commitment to the highest standards of academic excell…
Savings & BenefitsGet a snapshot of how the D’MAND CIRC works and the main features, benefits, and achievements of the product. To better read the information about D’MAND CIRC®, please …
Equity Residential: Case StudyTo better read the article, please use the fullscreen option in the lower right corner of the article or download below. Case Study Text: In the summer of 2010, executives at Enova…
Welk Resorts: Case StudyTo better read the article, please use the fullscreen option in the lower right corner of the article or download below. Welk Case Study Text: Water and energy efficiency ha…
Marriott Desert Villas: Case StudyTo better read the article, please use the fullscreen option in the lower right corner of the article or download below. Case Study Text: The objective of this case study was to de…
William Penn Apts: Case StudyTo better read the article, please use the fullscreen option in the lower right corner of the article or download below. William Penn Apts: Case Study Text: In this case study, Eno…
Oxford Club Apts: Case StudyThis case study describes how D’MAND CIRC® saves building owners thousands of dollars per year with a simple retrofit on their central water heating system. To better read th…
On-Demand Efficiency ProgramLearn more about the savings achieved through the ODE rebate program that is currently being conducted in Southern California. To better read the article, please use the fullscreen…
Pinhole Leak: Case StudyThis case study describes how using the D’MAND CIRC® helps to reduce pinhole leaks on a hot water recirculation loop. To better read the article, please use the fullscreen op…
Archstone/Tunlaw Garden Apts: Case StudyRead about the energy savings from a pair of D’MAND CIRC® installations at the Archstone apartment buildings in Washington, DC. To better read the article, please use the ful…
-
D’MAND CIRC® VIDEOClick To See How It Works -
Enovative Kontrol Systems VideoEnovative Kontrol Systems provides the most efficient means of delivering hot water through use of D’MAND CIRC®. This quick, concise video provides an excellent overview of the company and its pump. -
Installation Instruction VideoThis is a 5 minute installation video. This will give you an idea of what a typical installation looks like. (Note: This is not meant for training purposes) For contractors, please contact us before your first installation for detailed instructions.